Actual case
Use Case PICOGEN
Continuous monitoring of quality
Monitoring of water turbidity levels
The solution Save Innovations
CONFIGURATION
Pipe diameter: DN200
Average flow rate: 112 m³/h
Pressure: 0.2 bar
Allowable pressure drop: 0.1 bar
NEED
336 Wh/day, or 14 Wh continuously
1 turbidity meter
1 remote transmitter
PERFORMANCE
384 Wh/day, or 16 Wh continuously
0.07 bar pressure drop
Issues
Ensure the quality of the distributed water.
Objectives
Continuously monitor the turbidity level at the reservoir inlet.
Requirements
The operator is looking for an autonomous power supply solution for a turbidity meter and a remote transmitter.
Constraints
The site is a mountain reservoir located in a remote area, so connecting to the EDF grid would be too expensive.
Stakeholders
Engineering office and water services of a metropolitan area.